Why Normally open (NO) contact in PLC Programming? - Purpose & Use Cases
Imagine you have a factory machine that needs to start only when a button is pressed. Without automation, someone must watch and press the button every time, which is tiring and easy to miss.
Manually watching and pressing the button is slow and can cause mistakes. If the operator is distracted or tired, the machine might not start on time, causing delays or errors in production.
The Normally Open (NO) contact in PLC programming acts like a smart switch that closes the circuit only when the button is pressed. This lets the machine start automatically and reliably without constant human attention.
if button_pressed == True: start_machine()
NO_contact = button_input
if NO_contact:
start_machine()It enables machines to respond instantly and safely to user actions without manual monitoring.
In an assembly line, pressing a start button closes the NO contact, triggering the conveyor belt to move automatically, improving speed and safety.
Manual control is slow and error-prone.
Normally Open contact automates response to inputs.
This improves reliability and efficiency in machines.
Practice
Normally Open (NO) contact do in a PLC circuit?Solution
Step 1: Understand NO contact default state
A Normally Open contact is open by default, meaning no current flows through it initially.Step 2: Behavior when activated
When the NO contact is activated (e.g., button pressed), it closes, allowing current to flow.Final Answer:
It remains open until activated, then closes to allow current flow. -> Option AQuick Check:
NO contact = open by default, closes when activated [OK]
- Confusing NO with Normally Closed (NC) contact
- Thinking NO contact is closed by default
- Assuming NO contact always stays open
Solution
Step 1: Identify NO contact symbol
The Normally Open contact is represented by two parallel vertical lines:| |.Step 2: Differentiate from NC contact
The Normally Closed contact uses|/|or--[/]--symbols, which are different.Final Answer:
| |symbol -> Option CQuick Check:
NO contact =| |[OK]
- Using NC contact symbol for NO contact
- Confusing ladder logic symbols
- Mixing up contact and coil symbols
Start_Button controlling a coil Motor, what happens when Start_Button is pressed?
--| |--( )-- Start_Button Motor
Solution
Step 1: Analyze NO contact behavior when pressed
Pressing theStart_Buttoncloses the NO contact, allowing current to flow.Step 2: Effect on coil
Current energizes theMotorMotorcoil, turning the motor ON.Final Answer:
Motor coil energizes, turning the motor ON. -> Option BQuick Check:
NO contact pressed = coil energized [OK]
- Assuming coil de-energizes when NO contact closes
- Thinking NO contact does not affect coil
- Confusing coil with contact behavior
Sensor is supposed to start the Conveyor motor. However, the motor never starts even when the sensor is triggered. What is the likely error?
--|/|--( )-- Sensor Conveyor
Solution
Step 1: Identify contact type in code
The contact symbol|/|represents a Normally Closed (NC) contact, not Normally Open (NO).Step 2: Effect of NC contact on motor start
Since the sensor is triggered (activated), the NC contact opens, breaking the circuit and preventing the motor from starting.Final Answer:
The contact is Normally Closed (NC) instead of Normally Open (NO). -> Option AQuick Check:
Wrong contact type = motor won't start [OK]
- Confusing NC and NO contact symbols
- Assuming coil wiring is always the issue
- Ignoring sensor physical connection
Solution
Step 1: Understand NO contact behavior in start circuit
A Normally Open start button is open by default, meaning no current flows through it initially (machine OFF).Step 2: Effect of pressing NO start button
When the NO button is pressed, it closes, allowing current to flow and energizing the motor coil to start the machine.Final Answer:
Use the NO contact in series with the motor coil; pressing the button energizes the coil to start the machine. -> Option DQuick Check:
NO series press = coil energized to start [OK]
- Placing NO contact in parallel for start function
- Assuming pressing NO button breaks circuit to start
- Confusing NO and NC contacts in control circuits