PLC Programmingscripting~5 mins

NOT logic with NC contact in PLC Programming

Choose your learning style10 modes available
Introduction
NOT logic with NC contact helps control machines by turning things off when a switch is pressed. It uses a switch that is normally closed, so the machine stops when the switch opens.
Stopping a motor when a safety door is opened.
Turning off a light when a button is pressed.
Pausing a conveyor belt when an emergency stop is activated.
Preventing a machine from running if a guard is not in place.
Syntax
PLC Programming
NC Contact (Normally Closed) is used to represent NOT logic.
In ladder logic, it looks like a contact that is closed when not pressed and opens when pressed.
NC contact means the circuit is complete when the switch is not pressed.
When the NC contact opens, it breaks the circuit, stopping the output.
Examples
This ladder rung shows a normally closed contact controlling an output. The output is ON when the contact is closed (not pressed).
PLC Programming
----[ NC ]----( )

Where [ NC ] is a normally closed contact,
and ( ) is the output coil.
Motor runs only if Stop button (NC) is not pressed and Start button (NO) is pressed.
PLC Programming
----[ NC Stop ]----[ NO Start ]----( Motor )
Sample Program
This program shows how a normally closed Stop button and a normally open Start button control a motor. The motor runs only if Stop is not pressed and Start is pressed.
PLC Programming
(* Ladder logic example in structured text style for clarity *)
VAR
  StopButton : BOOL := TRUE; (* NC contact, TRUE means not pressed *)
  StartButton : BOOL := FALSE; (* NO contact, FALSE means not pressed *)
  Motor : BOOL := FALSE;
END_VAR

(* Motor runs if StopButton is TRUE (not pressed) and StartButton is TRUE (pressed) *)
Motor := StopButton AND StartButton;

(* Simulate pressing StartButton *)
StartButton := TRUE;
Motor := StopButton AND StartButton;

(* Simulate pressing StopButton (opens NC contact) *)
StopButton := FALSE;
Motor := StopButton AND StartButton;
OutputSuccess
Important Notes
NC contacts are safety features because they stop machines if wiring breaks or buttons are pressed.
Always test your logic in a safe environment before using it on real machines.
Summary
NOT logic with NC contact means the circuit is ON when the switch is not pressed.
Pressing the NC switch opens the circuit and stops the output.
This logic is useful for safety stops and emergency controls.

Practice

(1/5)
1. What does a Normally Closed (NC) contact represent in PLC logic?
easy
A. The circuit is ON when the switch is NOT pressed
B. The circuit is ON only when the switch is pressed
C. The circuit is always OFF
D. The circuit toggles ON and OFF automatically

Solution

  1. Step 1: Understand NC contact behavior

    An NC contact means the circuit is closed (ON) when the switch is not pressed.
  2. Step 2: Compare options with NC contact logic

    Only The circuit is ON when the switch is NOT pressed correctly states the circuit is ON when the switch is NOT pressed.
  3. Final Answer:

    The circuit is ON when the switch is NOT pressed -> Option A
  4. Quick Check:

    NC contact = ON when NOT pressed [OK]
Hint: NC means circuit closed when switch is NOT pressed [OK]
Common Mistakes:
  • Confusing NC with Normally Open (NO) contact
  • Thinking circuit is ON when switch is pressed
  • Assuming NC contact toggles automatically
2. Which of the following is the correct PLC ladder logic symbol for a Normally Closed (NC) contact?
easy
A. --|&|--
B. --| |--
C. --|/|--
D. --|X|--

Solution

  1. Step 1: Recall PLC contact symbols

    Normally Open (NO) contact is --| |--, Normally Closed (NC) contact is --|/|--.
  2. Step 2: Match symbol to NC contact

    --|/|-- shows --|/|--, which is the correct NC contact symbol.
  3. Final Answer:

    --|/|-- -> Option C
  4. Quick Check:

    NC contact symbol = --|/|-- [OK]
Hint: NC contact symbol has a slash / inside brackets [OK]
Common Mistakes:
  • Choosing NO contact symbol instead of NC
  • Confusing symbols with AND/OR logic
  • Using invalid or made-up symbols
3. Given this PLC ladder logic snippet with an NC contact labeled Stop controlling output Motor:
--|/|--(Stop)----( )--(Motor)
What happens to Motor when the Stop button is pressed?
medium
A. Motor turns OFF
B. Motor toggles ON and OFF rapidly
C. Motor turns ON
D. Motor state does not change

Solution

  1. Step 1: Understand NC contact effect when pressed

    Pressing the NC contact opens the circuit, breaking the path.
  2. Step 2: Determine output state

    Since the circuit is open, the Motor output coil is not energized and turns OFF.
  3. Final Answer:

    Motor turns OFF -> Option A
  4. Quick Check:

    Pressing NC contact = circuit open = output OFF [OK]
Hint: Pressing NC opens circuit, output turns OFF [OK]
Common Mistakes:
  • Assuming pressing NC turns output ON
  • Thinking output toggles automatically
  • Ignoring NC contact behavior
4. A PLC program uses an NC contact named EmergencyStop to stop a conveyor motor. The motor never stops when the emergency button is pressed. What is the most likely error?
medium
A. The PLC is powered off
B. The NC contact is wired as Normally Open (NO)
C. The emergency button is not pressed long enough
D. The output coil is missing

Solution

  1. Step 1: Analyze symptom

    Motor never stops when emergency button pressed means circuit does not open.
  2. Step 2: Identify wiring error

    If NC contact is wired as NO, pressing button closes circuit instead of opening it, so motor stays ON.
  3. Final Answer:

    The NC contact is wired as Normally Open (NO) -> Option B
  4. Quick Check:

    Wrong contact type wiring = motor won't stop [OK]
Hint: Check contact type wiring if stop fails [OK]
Common Mistakes:
  • Blaming output coil without checking input wiring
  • Assuming button press duration causes issue
  • Ignoring PLC power status
5. You want to design a safety stop circuit using an NC contact SafetySwitch and an output coil MachineRun. Which ladder logic rung correctly implements the NOT logic with the NC contact to stop the machine when the switch is pressed?
hard
A. --| |--(SafetySwitch)----( )--(MachineRun)
B. --| |--(MachineRun)----( )--(SafetySwitch)
C. --|/|--(MachineRun)----( )--(SafetySwitch)
D. --|/|--(SafetySwitch)----( )--(MachineRun)

Solution

  1. Step 1: Identify correct NC contact usage

    Safety stop uses NC contact so circuit is closed (MachineRun ON) when switch NOT pressed.
  2. Step 2: Match ladder logic rung

    --|/|--(SafetySwitch)----( )--(MachineRun) uses NC contact --|/|-- controlling MachineRun output correctly.
  3. Final Answer:

    --|/|--(SafetySwitch)----( )--(MachineRun) -> Option D
  4. Quick Check:

    NC contact before output coil = safety stop logic [OK]
Hint: Use NC contact before output coil for safety stop [OK]
Common Mistakes:
  • Using NO contact instead of NC for safety stop
  • Reversing contact and coil positions
  • Confusing contact labels with output coil