What does a Normally Open (NO) contact represent in PLC programming?
A Normally Open (NO) contact represents a switch that is open (off) when not activated. It closes (turns on) when the input condition is true, allowing current or signal to pass.
Click to reveal answer
beginner
How does a Normally Open (NO) contact behave when the input signal is false?
When the input signal is false, the NO contact remains open, so no current or signal passes through it.
Click to reveal answer
beginner
In ladder logic, what symbol usually represents a Normally Open (NO) contact?
A pair of parallel vertical lines with a gap between them represents a Normally Open (NO) contact in ladder logic diagrams.
Click to reveal answer
intermediate
Why is a Normally Open (NO) contact useful in automation control?
NO contacts are useful because they only allow current flow when a condition is met, making them ideal for controlling devices that should activate only on demand.
Click to reveal answer
beginner
What happens to a Normally Open (NO) contact when the associated input turns true in a PLC program?
When the input turns true, the NO contact closes, completing the circuit and allowing the output or next instruction to activate.
Click to reveal answer
What is the default state of a Normally Open (NO) contact?
AOpen (off)
BClosed (on)
CShort-circuited
DAlways energized
✗ Incorrect
A Normally Open contact is open by default and closes only when activated.
In ladder logic, what does a closed NO contact indicate?
AInput condition is false
BCircuit is broken
COutput is off
DInput condition is true
✗ Incorrect
A closed NO contact means the input condition is true, allowing current flow.
Which of the following best describes a Normally Open contact?
AIt closes when the input is true
BIt closes when the input is false
CIt is always closed
DIt is always open
✗ Incorrect
NO contacts close only when the input condition is true.
Why use a Normally Open contact in a control circuit?
ATo prevent any current flow
BTo keep devices always on
CTo activate devices only when needed
DTo create a permanent connection
✗ Incorrect
NO contacts allow devices to activate only when the control condition is met.
What happens if the input to a NO contact is false?
AThe contact reverses
BThe contact stays open
CThe contact shorts
DThe contact closes
✗ Incorrect
If the input is false, the NO contact remains open, blocking current.
Explain how a Normally Open (NO) contact works in a PLC ladder logic diagram.
Think about when the contact lets electricity pass.
You got /4 concepts.
Describe a real-life example where a Normally Open contact would be used in automation.
Consider a doorbell or a start button.
You got /4 concepts.
Practice
(1/5)
1. What does a Normally Open (NO) contact do in a PLC circuit?
easy
A. It remains open until activated, then closes to allow current flow.
B. It remains closed until activated, then opens to stop current flow.
C. It always stays closed regardless of activation.
D. It always stays open regardless of activation.
Solution
Step 1: Understand NO contact default state
A Normally Open contact is open by default, meaning no current flows through it initially.
Step 2: Behavior when activated
When the NO contact is activated (e.g., button pressed), it closes, allowing current to flow.
Final Answer:
It remains open until activated, then closes to allow current flow. -> Option A
Quick Check:
NO contact = open by default, closes when activated [OK]
Hint: NO means open until pressed, then closes [OK]
Common Mistakes:
Confusing NO with Normally Closed (NC) contact
Thinking NO contact is closed by default
Assuming NO contact always stays open
2. Which of the following is the correct syntax to represent a Normally Open (NO) contact in a PLC ladder logic program?
easy
A. --[/]-- symbol
B. |/| symbol
C. | | symbol
D. --[ ]-- symbol
Solution
Step 1: Identify NO contact symbol
The Normally Open contact is represented by two parallel vertical lines: | |.
Step 2: Differentiate from NC contact
The Normally Closed contact uses |/| or --[/]-- symbols, which are different.
Final Answer:
| | symbol -> Option C
Quick Check:
NO contact = | | [OK]
Hint: NO contact looks like two parallel lines | | [OK]
Common Mistakes:
Using NC contact symbol for NO contact
Confusing ladder logic symbols
Mixing up contact and coil symbols
3. Given the following ladder logic snippet with a Normally Open (NO) contact named Start_Button controlling a coil Motor, what happens when Start_Button is pressed?
--| |--( )--
Start_Button Motor
medium
A. Motor coil de-energizes, turning the motor OFF.
B. Motor coil energizes, turning the motor ON.
C. Nothing happens; the motor state remains unchanged.
D. Motor coil toggles ON and OFF rapidly.
Solution
Step 1: Analyze NO contact behavior when pressed
Pressing the Start_Button closes the NO contact, allowing current to flow.
Step 2: Effect on coil Motor
Current energizes the Motor coil, turning the motor ON.
Final Answer:
Motor coil energizes, turning the motor ON. -> Option B
Quick Check:
NO contact pressed = coil energized [OK]
Hint: Pressing NO contact energizes coil [OK]
Common Mistakes:
Assuming coil de-energizes when NO contact closes
Thinking NO contact does not affect coil
Confusing coil with contact behavior
4. In the ladder logic below, the Normally Open (NO) contact Sensor is supposed to start the Conveyor motor. However, the motor never starts even when the sensor is triggered. What is the likely error?
--|/|--( )--
Sensor Conveyor
medium
A. The contact is Normally Closed (NC) instead of Normally Open (NO).
B. The coil Conveyor is wired incorrectly.
C. The sensor is not physically connected.
D. The power supply is off.
Solution
Step 1: Identify contact type in code
The contact symbol |/| represents a Normally Closed (NC) contact, not Normally Open (NO).
Step 2: Effect of NC contact on motor start
Since the sensor is triggered (activated), the NC contact opens, breaking the circuit and preventing the motor from starting.
Final Answer:
The contact is Normally Closed (NC) instead of Normally Open (NO). -> Option A
Quick Check:
Wrong contact type = motor won't start [OK]
Hint: Check contact symbol: |/| means NC, not NO [OK]
Common Mistakes:
Confusing NC and NO contact symbols
Assuming coil wiring is always the issue
Ignoring sensor physical connection
5. You want to design a control circuit where a Normally Open (NO) start button must be pressed to start a machine. Which logic setup correctly uses the NO contact to achieve this?
hard
A. Use the NO contact in series with the motor coil; pressing the button breaks the circuit to start the machine.
B. Use the NO contact in parallel with the motor coil; pressing the button breaks the circuit to start the machine.
C. Use the NO contact in parallel with the motor coil; pressing the button energizes the coil to start the machine.
D. Use the NO contact in series with the motor coil; pressing the button energizes the coil to start the machine.
Solution
Step 1: Understand NO contact behavior in start circuit
A Normally Open start button is open by default, meaning no current flows through it initially (machine OFF).
Step 2: Effect of pressing NO start button
When the NO button is pressed, it closes, allowing current to flow and energizing the motor coil to start the machine.
Final Answer:
Use the NO contact in series with the motor coil; pressing the button energizes the coil to start the machine. -> Option D
Quick Check:
NO series press = coil energized to start [OK]
Hint: NO start button in series energizes coil when pressed [OK]
Common Mistakes:
Placing NO contact in parallel for start function
Assuming pressing NO button breaks circuit to start
Confusing NO and NC contacts in control circuits