Normally open (NO) contact in PLC Programming - Practice Problems & Coding Challenges

Choose your learning style10 modes available
Challenge - 5 Problems
🎖️
NO Contact Mastery
Get all challenges correct to earn this badge!
Test your skills under time pressure!
💻 Command Output
intermediate
2:00remaining
Output of a Normally Open (NO) Contact in Ladder Logic
In a PLC ladder logic program, a Normally Open (NO) contact is connected to an input X and an output coil Y. When input X is energized (true), what will be the state of output Y?
PLC Programming
----[ ]----( )----
     X       Y
AOutput Y is always energized regardless of input X.
BOutput Y is energized (true) only when input X is false.
COutput Y is energized (true) only when input X is true.
DOutput Y is never energized regardless of input X.
Attempts:
2 left
💡 Hint
Think about how a Normally Open contact behaves when the input is true or false.
🧠 Conceptual
intermediate
1:30remaining
Behavior of Normally Open (NO) Contact in a Control Circuit
Which statement best describes the behavior of a Normally Open (NO) contact in a control circuit?
AIt allows current to flow only when the controlling input is active (true).
BIt never allows current flow regardless of the controlling input.
CIt always allows current flow regardless of the controlling input.
DIt blocks current flow when the controlling input is active (true).
Attempts:
2 left
💡 Hint
Consider what happens to the contact when the input signal changes.
🔧 Debug
advanced
2:30remaining
Identify the Error in Ladder Logic Using NO Contact
Given the ladder logic snippet below, what is the error that prevents output Y from energizing when input X is true? ----[ ]----( )---- X Y Options:
AThe output coil Y is missing from the circuit.
BThere is no error; the output Y will energize correctly.
CThe input X is not connected to the NO contact.
DThe NO contact is incorrectly wired as Normally Closed (NC).
Attempts:
2 left
💡 Hint
Check if the NO contact and output coil are correctly represented.
🚀 Application
advanced
3:00remaining
Using NO Contact to Control a Motor Start
In a motor control circuit, a Normally Open (NO) push button is used to start the motor. Which of the following describes the correct operation?
AThe NO push button has no effect on the motor starter coil.
BPressing the NO push button opens the contact, de-energizing the motor starter coil.
CThe NO push button keeps the motor starter coil energized at all times.
DPressing the NO push button closes the contact, energizing the motor starter coil.
Attempts:
2 left
💡 Hint
Think about what happens when you press a Normally Open push button.
📝 Syntax
expert
2:30remaining
Correct Syntax for Representing a Normally Open Contact in Structured Text
Which of the following Structured Text code snippets correctly represents a Normally Open (NO) contact controlling output Y based on input X?
AY := X;
BY := NOT X;
CY := X AND NOT Y;
DY := TRUE;
Attempts:
2 left
💡 Hint
A NO contact passes the input signal directly to the output when true.

Practice

(1/5)
1. What does a Normally Open (NO) contact do in a PLC circuit?
easy
A. It remains open until activated, then closes to allow current flow.
B. It remains closed until activated, then opens to stop current flow.
C. It always stays closed regardless of activation.
D. It always stays open regardless of activation.

Solution

  1. Step 1: Understand NO contact default state

    A Normally Open contact is open by default, meaning no current flows through it initially.
  2. Step 2: Behavior when activated

    When the NO contact is activated (e.g., button pressed), it closes, allowing current to flow.
  3. Final Answer:

    It remains open until activated, then closes to allow current flow. -> Option A
  4. Quick Check:

    NO contact = open by default, closes when activated [OK]
Hint: NO means open until pressed, then closes [OK]
Common Mistakes:
  • Confusing NO with Normally Closed (NC) contact
  • Thinking NO contact is closed by default
  • Assuming NO contact always stays open
2. Which of the following is the correct syntax to represent a Normally Open (NO) contact in a PLC ladder logic program?
easy
A. --[/]-- symbol
B. |/| symbol
C. | | symbol
D. --[ ]-- symbol

Solution

  1. Step 1: Identify NO contact symbol

    The Normally Open contact is represented by two parallel vertical lines: | |.
  2. Step 2: Differentiate from NC contact

    The Normally Closed contact uses |/| or --[/]-- symbols, which are different.
  3. Final Answer:

    | | symbol -> Option C
  4. Quick Check:

    NO contact = | | [OK]
Hint: NO contact looks like two parallel lines | | [OK]
Common Mistakes:
  • Using NC contact symbol for NO contact
  • Confusing ladder logic symbols
  • Mixing up contact and coil symbols
3. Given the following ladder logic snippet with a Normally Open (NO) contact named Start_Button controlling a coil Motor, what happens when Start_Button is pressed?
--| |--( )--
  Start_Button  Motor
medium
A. Motor coil de-energizes, turning the motor OFF.
B. Motor coil energizes, turning the motor ON.
C. Nothing happens; the motor state remains unchanged.
D. Motor coil toggles ON and OFF rapidly.

Solution

  1. Step 1: Analyze NO contact behavior when pressed

    Pressing the Start_Button closes the NO contact, allowing current to flow.
  2. Step 2: Effect on coil Motor

    Current energizes the Motor coil, turning the motor ON.
  3. Final Answer:

    Motor coil energizes, turning the motor ON. -> Option B
  4. Quick Check:

    NO contact pressed = coil energized [OK]
Hint: Pressing NO contact energizes coil [OK]
Common Mistakes:
  • Assuming coil de-energizes when NO contact closes
  • Thinking NO contact does not affect coil
  • Confusing coil with contact behavior
4. In the ladder logic below, the Normally Open (NO) contact Sensor is supposed to start the Conveyor motor. However, the motor never starts even when the sensor is triggered. What is the likely error?
--|/|--( )--
 Sensor Conveyor
medium
A. The contact is Normally Closed (NC) instead of Normally Open (NO).
B. The coil Conveyor is wired incorrectly.
C. The sensor is not physically connected.
D. The power supply is off.

Solution

  1. Step 1: Identify contact type in code

    The contact symbol |/| represents a Normally Closed (NC) contact, not Normally Open (NO).
  2. Step 2: Effect of NC contact on motor start

    Since the sensor is triggered (activated), the NC contact opens, breaking the circuit and preventing the motor from starting.
  3. Final Answer:

    The contact is Normally Closed (NC) instead of Normally Open (NO). -> Option A
  4. Quick Check:

    Wrong contact type = motor won't start [OK]
Hint: Check contact symbol: |/| means NC, not NO [OK]
Common Mistakes:
  • Confusing NC and NO contact symbols
  • Assuming coil wiring is always the issue
  • Ignoring sensor physical connection
5. You want to design a control circuit where a Normally Open (NO) start button must be pressed to start a machine. Which logic setup correctly uses the NO contact to achieve this?
hard
A. Use the NO contact in series with the motor coil; pressing the button breaks the circuit to start the machine.
B. Use the NO contact in parallel with the motor coil; pressing the button breaks the circuit to start the machine.
C. Use the NO contact in parallel with the motor coil; pressing the button energizes the coil to start the machine.
D. Use the NO contact in series with the motor coil; pressing the button energizes the coil to start the machine.

Solution

  1. Step 1: Understand NO contact behavior in start circuit

    A Normally Open start button is open by default, meaning no current flows through it initially (machine OFF).
  2. Step 2: Effect of pressing NO start button

    When the NO button is pressed, it closes, allowing current to flow and energizing the motor coil to start the machine.
  3. Final Answer:

    Use the NO contact in series with the motor coil; pressing the button energizes the coil to start the machine. -> Option D
  4. Quick Check:

    NO series press = coil energized to start [OK]
Hint: NO start button in series energizes coil when pressed [OK]
Common Mistakes:
  • Placing NO contact in parallel for start function
  • Assuming pressing NO button breaks circuit to start
  • Confusing NO and NC contacts in control circuits
Recommended

Ready to prove it?

Pass the test and this pattern moves unknown strong while earning +1 Grip toward your certificate.

10 questions~5 mineasy hard