Introduction
An emergency stop is used to quickly and safely stop a machine to prevent accidents or damage.
IF Emergency_Stop_Button = TRUE THEN
Machine_Run := FALSE;
END_IF;IF Emergency_Stop_Button THEN
Machine_Run := FALSE;
END_IF;IF NOT Emergency_Stop_Button THEN
Machine_Run := TRUE;
ELSE
Machine_Run := FALSE;
END_IF;PROGRAM EmergencyStop
VAR
Emergency_Stop_Button : BOOL; (* Input from emergency stop switch *)
Machine_Run : BOOL; (* Output to control machine *)
END_VAR
(* Main logic *)
IF Emergency_Stop_Button THEN
Machine_Run := FALSE; (* Stop machine immediately *)
ELSE
Machine_Run := TRUE; (* Allow machine to run *)
END_IF;
END_PROGRAMESTOP in ladder logic?--|/|--[ESTOP]----( )--[MOTOR_RUN]
MOTOR_RUN when the emergency stop button is pressed?--| |--[ESTOP]----( )--[MOTOR_RUN]
--|/|--[ESTOP]----+----( )--[MOTOR_RUN]
|
--| |--[START]----+Pass the test and this pattern moves unknown