PLC Programmingscripting~10 mins

Output coil in PLC Programming - Step-by-Step Execution

Choose your learning style10 modes available
Concept Flow - Output coil
Input Condition
↓
Evaluate Condition
Yes↓
Set Output Coil ON
↓
END
No↓
Set Output Coil OFF
↓
END
The output coil turns ON if the input condition is true; otherwise, it turns OFF.
Execution Sample
PLC Programming
LD X0
OUT Y0
If input X0 is ON, output coil Y0 turns ON; if X0 is OFF, Y0 turns OFF.
Execution Table
StepInput X0ActionOutput Y0
1ONSet Y0 ONON
2OFFSet Y0 OFFOFF
💡 Execution ends after setting output coil based on input condition.
Variable Tracker
VariableStartAfter Step 1After Step 2
X0OFFONOFF
Y0OFFONOFF
Key Moments - 2 Insights
Why does the output coil Y0 turn OFF when input X0 is OFF?
Because the output coil directly follows the input condition. When X0 is OFF (see execution_table step 2), the coil is set OFF to match the input state.
Can the output coil be ON if the input is OFF?
No, the output coil only turns ON when the input condition is true (ON). This is shown in execution_table step 1 where X0 is ON and Y0 is set ON.
Visual Quiz - 3 Questions
Test your understanding
Look at the execution table, what is the state of output Y0 at step 1?
AOFF
BON
CUndefined
DFlashing
💡 Hint
Check the 'Output Y0' column in execution_table row for step 1.
At which step does the input X0 become OFF?
AStep 2
BNever
CStep 1
DBoth steps
💡 Hint
Look at the 'Input X0' column in execution_table for each step.
If input X0 stays ON, what will happen to output Y0?
AY0 will toggle ON and OFF
BY0 will turn OFF
CY0 will stay ON
DY0 will stay OFF
💡 Hint
Refer to variable_tracker to see how Y0 changes when X0 is ON.
Concept Snapshot
Output coil turns ON when input condition is true.
If input is OFF, output coil turns OFF.
Syntax example: LD X0; OUT Y0
Used to control devices like motors or lights.
Directly reflects input state in output coil.
Full Transcript
An output coil in PLC programming is a command that controls an output device. It turns ON when the input condition is true and turns OFF when the input is false. For example, if input X0 is ON, the output coil Y0 will be set ON, activating the connected device. If X0 is OFF, Y0 will be OFF, turning the device off. This simple logic ensures the output coil always matches the input condition. The execution table shows two steps: when X0 is ON, Y0 is ON; when X0 is OFF, Y0 is OFF. The variable tracker confirms these state changes. Beginners often wonder why the coil turns OFF when input is OFF; it is because the coil directly follows the input condition. This concept is fundamental for controlling outputs in automation.

Practice

(1/5)
1. What is the main purpose of an output coil in PLC programming?
easy
A. To control devices like lights or motors by turning them ON or OFF
B. To read input signals from sensors
C. To store data temporarily
D. To perform mathematical calculations

Solution

  1. Step 1: Understand the role of output coils

    Output coils are used to control physical devices by turning them ON or OFF based on program logic.
  2. Step 2: Differentiate from other PLC elements

    Input signals are read by input instructions, data storage is done by registers, and calculations are done by math instructions, not output coils.
  3. Final Answer:

    To control devices like lights or motors by turning them ON or OFF -> Option A
  4. Quick Check:

    Output coil controls devices = B [OK]
Hint: Output coils always control devices ON/OFF [OK]
Common Mistakes:
  • Confusing output coils with input instructions
  • Thinking output coils store data
  • Assuming output coils perform calculations
2. Which of the following is the correct syntax to define an output coil named Motor in ladder logic?
easy
A. ( ) Motor
B. COIL Motor
C. OUT Motor
D. SET Motor

Solution

  1. Step 1: Recognize ladder logic output coil symbol

    In ladder logic, output coils are represented by parentheses around the coil name, like ( ) Motor.
  2. Step 2: Compare other options

    OUT and SET are instructions but not standard coil syntax; COIL is not a typical keyword.
  3. Final Answer:

    ( ) Motor -> Option A
  4. Quick Check:

    Output coil uses parentheses = A [OK]
Hint: Output coils use parentheses in ladder logic [OK]
Common Mistakes:
  • Using keywords like OUT or SET instead of parentheses
  • Confusing coil syntax with input instructions
  • Omitting parentheses around coil name
3. Given the ladder logic snippet:
( ) Light
--[ ] Switch
What happens when the Switch input is ON?
medium
A. Nothing changes
B. The Light output coil turns ON
C. The Switch input turns OFF
D. The Light output coil turns OFF

Solution

  1. Step 1: Understand the ladder logic flow

    The normally open contact [ ] Switch controls the output coil ( ) Light. When Switch is ON (closed), current flows to Light coil.
  2. Step 2: Determine output coil state

    Since Switch is ON, the Light coil energizes and turns ON the Light output.
  3. Final Answer:

    The Light output coil turns ON -> Option B
  4. Quick Check:

    Switch ON energizes Light coil = D [OK]
Hint: Input ON energizes output coil ON [OK]
Common Mistakes:
  • Thinking output coil turns OFF when input is ON
  • Confusing input and output roles
  • Assuming no change occurs
4. Identify the error in this ladder logic snippet:
( ) Motor
--[ ] Start
--[/] Stop
where [/] is a normally closed contact. The Motor never stays ON even when Start is pressed and Stop is released.
medium
A. The output coil syntax is incorrect
B. The Stop contact should be normally open, not normally closed
C. The contacts are not connected in parallel
D. The Start contact is wired incorrectly

Solution

  1. Step 1: Analyze contact wiring logic

    The Start and Stop contacts are in series, so both must be ON for Motor coil to energize.
  2. Step 2: Understand typical start/stop control

    Usually, Start and Stop contacts are wired in parallel or with a latch to maintain Motor ON after Start is pressed.
  3. Step 3: Identify wiring issue

    Because contacts are in series without latching, Motor never stays ON; wiring should be parallel or use latch logic.
  4. Final Answer:

    The contacts are not connected in parallel -> Option C
  5. Quick Check:

    Start/Stop need parallel or latch wiring = C [OK]
Hint: Start/Stop usually wired parallel or latched [OK]
Common Mistakes:
  • Assuming output coil syntax is wrong
  • Changing Stop contact type incorrectly
  • Not recognizing wiring arrangement
5. You want to control a valve using an output coil named Valve. The valve should turn ON only if both Pressure_OK and Temperature_OK inputs are ON. Which ladder logic snippet correctly implements this?
hard
A.
( ) Valve
--[/] Pressure_OK
--[ ] Temperature_OK
B.
( ) Valve
--[ ] Pressure_OK
--[/] Temperature_OK
C.
( ) Valve
--[ ] Pressure_OK
--| | Temperature_OK
D.
( ) Valve
--[ ] Pressure_OK
--[ ] Temperature_OK

Solution

  1. Step 1: Understand AND condition in ladder logic

    To turn Valve ON only if both inputs are ON, the contacts must be in series, both normally open.
  2. Step 2: Check each option

    ( ) Valve
    --[ ] Pressure_OK
    --[ ] Temperature_OK
    
    has both [ ] Pressure_OK and [ ] Temperature_OK in series, correct for AND logic.
    ( ) Valve
    --[ ] Pressure_OK
    --[/] Temperature_OK
    
    uses normally closed for Temperature_OK, wrong.
    ( ) Valve
    --[ ] Pressure_OK
    --| | Temperature_OK
    
    uses invalid symbol | |.
    ( ) Valve
    --[/] Pressure_OK
    --[ ] Temperature_OK
    
    uses normally closed for Pressure_OK, wrong.
  3. Final Answer:

    with both normally open contacts in series -> Option D
  4. Quick Check:

    Both inputs ON in series = Valve ON [OK]
Hint: AND logic uses series normally open contacts [OK]
Common Mistakes:
  • Using normally closed contacts incorrectly
  • Confusing AND with OR logic
  • Using invalid contact symbols