Output coil in PLC Programming - Interactive Code Practice

Choose your learning style10 modes available
Practice - 5 Tasks
Answer the questions below
1fill in blank
easy

Complete the code to turn on the output coil named 'Motor'.

PLC Programming
OUTPUT [1] ;
Drag options to blanks, or click blank then click option'
AMotor
BStart
CStop
DReset
Attempts:
3 left
💡 Hint
Common Mistakes
Using a wrong coil name like 'Start' or 'Stop'.
Forgetting the coil name after OUTPUT.
2fill in blank
medium

Complete the code to turn off the output coil named 'Light'.

PLC Programming
RESET [1] ;
Drag options to blanks, or click blank then click option'
APump
BFan
CLight
DValve
Attempts:
3 left
💡 Hint
Common Mistakes
Using the wrong coil name like 'Fan' or 'Pump'.
Using OUTPUT instead of RESET to turn off.
3fill in blank
hard

Fix the error in the code to turn on the output coil 'Conveyor'.

PLC Programming
OUTPUT [1] ;
Drag options to blanks, or click blank then click option'
AConveyor1
BConveryor
CConveyorBelt
DConveyor
Attempts:
3 left
💡 Hint
Common Mistakes
Misspelling the coil name.
Not noticing the typo in the command keyword.
4fill in blank
hard

Fill both blanks to set the output coil 'Heater' ON when input 'TempHigh' is true.

PLC Programming
IF [1] THEN
  OUTPUT [2] ;
END_IF
Drag options to blanks, or click blank then click option'
ATempHigh
BTempLow
CHeater
DCooler
Attempts:
3 left
💡 Hint
Common Mistakes
Using wrong input like 'TempLow'.
Activating the wrong coil like 'Cooler'.
5fill in blank
hard

Fill all three blanks to reset the output coil 'Alarm' when input 'ResetButton' is pressed and 'AlarmActive' is true.

PLC Programming
IF [1] AND [2] THEN
  RESET [3] ;
END_IF
Drag options to blanks, or click blank then click option'
AResetButton
BAlarmActive
CAlarm
DStartButton
Attempts:
3 left
💡 Hint
Common Mistakes
Using wrong inputs like 'StartButton'.
Resetting the wrong coil.

Practice

(1/5)
1. What is the main purpose of an output coil in PLC programming?
easy
A. To control devices like lights or motors by turning them ON or OFF
B. To read input signals from sensors
C. To store data temporarily
D. To perform mathematical calculations

Solution

  1. Step 1: Understand the role of output coils

    Output coils are used to control physical devices by turning them ON or OFF based on program logic.
  2. Step 2: Differentiate from other PLC elements

    Input signals are read by input instructions, data storage is done by registers, and calculations are done by math instructions, not output coils.
  3. Final Answer:

    To control devices like lights or motors by turning them ON or OFF -> Option A
  4. Quick Check:

    Output coil controls devices = B [OK]
Hint: Output coils always control devices ON/OFF [OK]
Common Mistakes:
  • Confusing output coils with input instructions
  • Thinking output coils store data
  • Assuming output coils perform calculations
2. Which of the following is the correct syntax to define an output coil named Motor in ladder logic?
easy
A. ( ) Motor
B. COIL Motor
C. OUT Motor
D. SET Motor

Solution

  1. Step 1: Recognize ladder logic output coil symbol

    In ladder logic, output coils are represented by parentheses around the coil name, like ( ) Motor.
  2. Step 2: Compare other options

    OUT and SET are instructions but not standard coil syntax; COIL is not a typical keyword.
  3. Final Answer:

    ( ) Motor -> Option A
  4. Quick Check:

    Output coil uses parentheses = A [OK]
Hint: Output coils use parentheses in ladder logic [OK]
Common Mistakes:
  • Using keywords like OUT or SET instead of parentheses
  • Confusing coil syntax with input instructions
  • Omitting parentheses around coil name
3. Given the ladder logic snippet:
( ) Light
--[ ] Switch
What happens when the Switch input is ON?
medium
A. Nothing changes
B. The Light output coil turns ON
C. The Switch input turns OFF
D. The Light output coil turns OFF

Solution

  1. Step 1: Understand the ladder logic flow

    The normally open contact [ ] Switch controls the output coil ( ) Light. When Switch is ON (closed), current flows to Light coil.
  2. Step 2: Determine output coil state

    Since Switch is ON, the Light coil energizes and turns ON the Light output.
  3. Final Answer:

    The Light output coil turns ON -> Option B
  4. Quick Check:

    Switch ON energizes Light coil = D [OK]
Hint: Input ON energizes output coil ON [OK]
Common Mistakes:
  • Thinking output coil turns OFF when input is ON
  • Confusing input and output roles
  • Assuming no change occurs
4. Identify the error in this ladder logic snippet:
( ) Motor
--[ ] Start
--[/] Stop
where [/] is a normally closed contact. The Motor never stays ON even when Start is pressed and Stop is released.
medium
A. The output coil syntax is incorrect
B. The Stop contact should be normally open, not normally closed
C. The contacts are not connected in parallel
D. The Start contact is wired incorrectly

Solution

  1. Step 1: Analyze contact wiring logic

    The Start and Stop contacts are in series, so both must be ON for Motor coil to energize.
  2. Step 2: Understand typical start/stop control

    Usually, Start and Stop contacts are wired in parallel or with a latch to maintain Motor ON after Start is pressed.
  3. Step 3: Identify wiring issue

    Because contacts are in series without latching, Motor never stays ON; wiring should be parallel or use latch logic.
  4. Final Answer:

    The contacts are not connected in parallel -> Option C
  5. Quick Check:

    Start/Stop need parallel or latch wiring = C [OK]
Hint: Start/Stop usually wired parallel or latched [OK]
Common Mistakes:
  • Assuming output coil syntax is wrong
  • Changing Stop contact type incorrectly
  • Not recognizing wiring arrangement
5. You want to control a valve using an output coil named Valve. The valve should turn ON only if both Pressure_OK and Temperature_OK inputs are ON. Which ladder logic snippet correctly implements this?
hard
A.
( ) Valve
--[/] Pressure_OK
--[ ] Temperature_OK
B.
( ) Valve
--[ ] Pressure_OK
--[/] Temperature_OK
C.
( ) Valve
--[ ] Pressure_OK
--| | Temperature_OK
D.
( ) Valve
--[ ] Pressure_OK
--[ ] Temperature_OK

Solution

  1. Step 1: Understand AND condition in ladder logic

    To turn Valve ON only if both inputs are ON, the contacts must be in series, both normally open.
  2. Step 2: Check each option

    ( ) Valve
    --[ ] Pressure_OK
    --[ ] Temperature_OK
    
    has both [ ] Pressure_OK and [ ] Temperature_OK in series, correct for AND logic.
    ( ) Valve
    --[ ] Pressure_OK
    --[/] Temperature_OK
    
    uses normally closed for Temperature_OK, wrong.
    ( ) Valve
    --[ ] Pressure_OK
    --| | Temperature_OK
    
    uses invalid symbol | |.
    ( ) Valve
    --[/] Pressure_OK
    --[ ] Temperature_OK
    
    uses normally closed for Pressure_OK, wrong.
  3. Final Answer:

    with both normally open contacts in series -> Option D
  4. Quick Check:

    Both inputs ON in series = Valve ON [OK]
Hint: AND logic uses series normally open contacts [OK]
Common Mistakes:
  • Using normally closed contacts incorrectly
  • Confusing AND with OR logic
  • Using invalid contact symbols
Recommended

Ready to prove it?

Pass the test and this pattern moves unknown strong while earning +1 Grip toward your certificate.

10 questions~5 mineasy hard