PLC Programmingscripting~10 mins

Star-delta starter using timers in PLC Programming - Interactive Code Practice

Choose your learning style10 modes available
Practice - 5 Tasks
Answer the questions below
1fill in blank
easy

Complete the code to start the star contactor using a timer.

PLC Programming
TON TimerStar(IN:=StartButton, PT:=T#[1]s, Q=>StarContactor);
Drag options to blanks, or click blank then click option'
A15
B5
C10
D20
Attempts:
3 left
💡 Hint
Common Mistakes
Using too short or too long timer values that can cause motor damage.
Confusing the timer preset time unit.
2fill in blank
medium

Complete the code to energize the delta contactor after the star timer is done.

PLC Programming
IF TimerStar.Q THEN DeltaContactor := [1]; END_IF;
Drag options to blanks, or click blank then click option'
AFALSE
BTRUE
CTimerStar.IN
DStartButton
Attempts:
3 left
💡 Hint
Common Mistakes
Setting DeltaContactor to FALSE instead of TRUE.
Using the timer input or start button instead of the timer output.
3fill in blank
hard

Fix the error in the timer reset logic to stop the star timer when the delta contactor is energized.

PLC Programming
TimerStar.IN := StartButton AND NOT [1];
Drag options to blanks, or click blank then click option'
AStarContactor
BTimerStar.Q
CStopButton
DDeltaContactor
Attempts:
3 left
💡 Hint
Common Mistakes
Using the star contactor or stop button instead of delta contactor.
Not negating the condition to reset the timer.
4fill in blank
hard

Fill both blanks to complete the logic that ensures the star contactor turns off when the delta contactor turns on.

PLC Programming
StarContactor := StartButton AND [1];
DeltaContactor := TimerStar.Q AND [2];
Drag options to blanks, or click blank then click option'
ANOT TimerStar.Q
BNOT StarContactor
CStartButton
DTimerStar.IN
Attempts:
3 left
💡 Hint
Common Mistakes
Not negating the timer output or star contactor in the conditions.
Using the start button incorrectly in delta contactor logic.
5fill in blank
hard

Fill all three blanks to create a dictionary that maps each contactor to its timer status and control signal.

PLC Programming
contactor_status = {
  '[1]': TimerStar.Q,
  '[2]': StartButton,
  '[3]': DeltaContactor
}
Drag options to blanks, or click blank then click option'
AStarContactor
BTimerStar
CDeltaContactor
DStartButton
Attempts:
3 left
💡 Hint
Common Mistakes
Mixing up keys and values in the dictionary.
Using variable names instead of string keys.

Practice

(1/5)
1. What is the main purpose of using timers in a star-delta starter circuit?
easy
A. To control the time the motor stays connected in star and delta modes
B. To increase the motor speed instantly
C. To change the motor direction automatically
D. To measure the motor temperature

Solution

  1. Step 1: Understand star-delta starter function

    The star-delta starter reduces starting current by initially connecting the motor in star mode, then switching to delta mode.
  2. Step 2: Role of timers in this process

    Timers control how long the motor stays in star mode before switching to delta mode to ensure smooth transition and reduce electrical stress.
  3. Final Answer:

    To control the time the motor stays connected in star and delta modes -> Option A
  4. Quick Check:

    Timers control connection time = A [OK]
Hint: Timers manage star and delta connection duration [OK]
Common Mistakes:
  • Thinking timers increase motor speed
  • Confusing timers with direction control
  • Assuming timers measure temperature
2. Which of the following is the correct way to declare a timer in a PLC program for star-delta starting?
easy
A. TIMER Timer1 (START=Start, TIME=5s, DONE=Done)
B. TON Timer1 (IN:=Start, PT:=T#5s, Q=>Done)
C. TON Timer1(IN:=Start, PT:=T#5s, Q=>Done);
D. Timer1 = TON(Start, 5)

Solution

  1. Step 1: Identify correct timer syntax in PLC

    In IEC 61131-3 standard, TON timers are declared with input IN, preset time PT, and output Q using := and => operators.
  2. Step 2: Compare options

    TON Timer1 (IN:=Start, PT:=T#5s, Q=>Done) uses correct syntax: TON Timer1 (IN:=Start, PT:=T#5s, Q=>Done). Others have syntax errors or incorrect format.
  3. Final Answer:

    TON Timer1 (IN:=Start, PT:=T#5s, Q=>Done) -> Option B
  4. Quick Check:

    Correct IEC timer syntax = B [OK]
Hint: Use TON with IN:=, PT:=, Q=> for timers [OK]
Common Mistakes:
  • Using incorrect assignment operators
  • Missing time format T#5s
  • Adding semicolons inside declarations
3. Given the following PLC code snippet for a star-delta starter:
IF Start THEN
  TimerStar(IN:=TRUE, PT:=T#10s);
  IF TimerStar.Q THEN
    TimerDelta(IN:=TRUE, PT:=T#5s);
  END_IF
END_IF

What is the output state of TimerDelta.Q after 12 seconds of Start being TRUE?
medium
A. TRUE
B. TimerDelta.Q resets to FALSE
C. Undefined
D. FALSE

Solution

  1. Step 1: Analyze TimerStar behavior

    TimerStar starts when Start is TRUE and runs for 10 seconds. After 10 seconds, TimerStar.Q becomes TRUE.
  2. Step 2: Analyze TimerDelta behavior after TimerStar.Q

    Once TimerStar.Q is TRUE (after 10s), TimerDelta starts and runs for 5 seconds. At 12 seconds, TimerDelta has been running for 2 seconds, so TimerDelta.Q is still FALSE. But the code only sets TimerDelta.IN to TRUE when TimerStar.Q is TRUE, so TimerDelta is active.
  3. Step 3: Re-examine timing

    At 12 seconds, TimerDelta has been running for 2 seconds (less than 5s), so TimerDelta.Q is FALSE.
  4. Final Answer:

    FALSE -> Option D
  5. Quick Check:

    TimerDelta.Q after 2s < 5s = FALSE [OK]
Hint: Timer output Q is TRUE only after preset time PT [OK]
Common Mistakes:
  • Assuming TimerDelta.Q is TRUE immediately
  • Ignoring timer preset times
  • Confusing timer input IN with output Q
4. Identify the error in this star-delta timer PLC code snippet:
IF Start THEN
  TimerStar(IN:=Start, PT:=T#10s);
  IF TimerStar.Q THEN
    TimerDelta(IN:=Start, PT:=T#5s);
  END_IF
END_IF

What is the main problem?
medium
A. TimerDelta never starts because IN is tied to Start, not TimerStar.Q
B. TimerStar timer preset time is too short
C. Start input is not used correctly
D. Timers are missing reset logic

Solution

  1. Step 1: Check TimerStar input

    TimerStar.IN is correctly tied to Start, so it runs when Start is TRUE.
  2. Step 2: Check TimerDelta input

    TimerDelta.IN is tied to Start, not TimerStar.Q. This means TimerDelta starts immediately with Start, not after TimerStar.Q becomes TRUE.
  3. Step 3: Identify the problem

    TimerDelta should start only after TimerStar.Q is TRUE to ensure star mode completes before delta starts. Current code starts TimerDelta too early.
  4. Final Answer:

    TimerDelta never starts because IN is tied to Start, not TimerStar.Q -> Option A
  5. Quick Check:

    TimerDelta.IN must depend on TimerStar.Q [OK]
Hint: TimerDelta.IN should depend on TimerStar.Q, not Start [OK]
Common Mistakes:
  • Linking TimerDelta.IN directly to Start
  • Ignoring timer sequence dependencies
  • Not resetting timers properly
5. You want to design a star-delta starter PLC program where the motor starts in star mode for 8 seconds, then switches to delta mode for 10 seconds, and finally stops. Which timer logic sequence correctly achieves this?
hard
A. Start triggers both TimerStar and TimerDelta simultaneously, motor stops after 18s
B. Start triggers TimerDelta (10s), when TimerDelta.Q is TRUE start TimerStar (8s), then stop motor
C. Start triggers TimerStar (8s), when TimerStar.Q is TRUE start TimerDelta (10s), when TimerDelta.Q is TRUE stop motor
D. Start triggers TimerStar (8s), motor stops immediately after TimerStar.Q is TRUE

Solution

  1. Step 1: Understand star-delta timing sequence

    The motor must start in star mode for 8 seconds, then switch to delta mode for 10 seconds, then stop.
  2. Step 2: Analyze options

    Start triggers TimerStar (8s), when TimerStar.Q is TRUE start TimerDelta (10s), when TimerDelta.Q is TRUE stop motor correctly sequences timers: TimerStar runs first, then TimerDelta starts after TimerStar.Q is TRUE, then motor stops after TimerDelta.Q is TRUE.
  3. Step 3: Eliminate incorrect options

    Start triggers TimerDelta (10s), when TimerDelta.Q is TRUE start TimerStar (8s), then stop motor reverses sequence, Start triggers both TimerStar and TimerDelta simultaneously, motor stops after 18s runs timers simultaneously (wrong), Start triggers TimerStar (8s), motor stops immediately after TimerStar.Q is TRUE stops motor too early.
  4. Final Answer:

    Start triggers TimerStar (8s), when TimerStar.Q is TRUE start TimerDelta (10s), when TimerDelta.Q is TRUE stop motor -> Option C
  5. Quick Check:

    Sequential timers for star then delta = C [OK]
Hint: Chain timers: star first, then delta, then stop [OK]
Common Mistakes:
  • Starting timers simultaneously
  • Reversing star and delta order
  • Stopping motor too early