intermediateOutput of INT to REAL conversion
What is the output value of the REAL variable after converting the INT value 123 using the standard INT_TO_REAL instruction?
PLC Programming
INT inputValue := 123;
REAL outputValue;
outputValue := INT_TO_REAL(inputValue);Attempts:
2 left
💡 Hint
Remember that INT_TO_REAL converts integer to floating point number preserving the value.
✗ Incorrect
The INT_TO_REAL instruction converts the integer 123 to the floating point number 123.0. It does not change the value, only the data type.
💻 Command Output
intermediateResult of BYTE to WORD conversion
Given a BYTE variable with value 255, what is the value of a WORD variable after conversion using BYTE_TO_WORD?
PLC Programming
BYTE byteVal := 255;
WORD wordVal;
wordVal := BYTE_TO_WORD(byteVal);Attempts:
2 left
💡 Hint
BYTE_TO_WORD converts 8-bit to 16-bit preserving the numeric value.
✗ Incorrect
BYTE_TO_WORD converts the 8-bit value 255 to a 16-bit WORD with the same numeric value 255.
📝 Syntax
advancedIdentify the correct syntax for converting REAL to INT
Which of the following code snippets correctly converts a REAL variable to an INT variable using the standard conversion instruction?
Attempts:
2 left
💡 Hint
Look for the standard IEC 61131-3 conversion function name.
✗ Incorrect
The correct syntax uses the standard IEC instruction REAL_TO_INT to convert REAL to INT. Other options are invalid or non-standard.
🔧 Debug
advancedDebugging data conversion overflow error
A program converts a DINT value 70000 to a WORD variable using DINT_TO_WORD. What will happen and why?
PLC Programming
DINT largeValue := 70000;
WORD smallValue;
smallValue := DINT_TO_WORD(largeValue);Attempts:
2 left
💡 Hint
WORD can only hold values up to 65535. Larger values wrap around.
✗ Incorrect
Converting 70000 to WORD causes overflow. The value wraps around modulo 65536, resulting in 70000 - 65536 = 4464.
🚀 Application
expertCombining multiple data conversions in a PLC program
You have a REAL sensor input that must be converted to an INT for processing, then to a BYTE for communication. Which sequence of instructions correctly performs these conversions without data loss or errors?
PLC Programming
REAL sensorInput := 123.45;
INT intValue;
BYTE byteValue;Attempts:
2 left
💡 Hint
Convert from REAL to INT first, then INT to BYTE. Avoid direct REAL to BYTE conversion.
✗ Incorrect
Option C uses standard IEC instructions REAL_TO_INT and INT_TO_BYTE in correct order. Other options use invalid or unsafe conversions.