Bird
Raised Fist0
PLC Programmingscripting~5 mins

On-delay timer (TON) behavior in PLC Programming

Choose your learning style10 modes available
Introduction

An on-delay timer (TON) waits for a set time before turning on its output after the input turns on. It helps control timing in machines and processes.

Start a motor only after a safety check has been on for 5 seconds.
Delay turning on a light after a switch is pressed.
Wait before opening a valve to avoid pressure spikes.
Control a conveyor belt to start after a delay when a sensor detects an item.
Syntax
PLC Programming
TimerName(IN:=InputSignal, PT:=PresetTime, Q=>OutputSignal, ET=>ElapsedTime);

IN is the input that starts the timer.

PT is the preset time to wait before output turns on.

Examples
This timer waits 5 seconds after StartButton is pressed before MotorOn turns true.
PLC Programming
Timer1(IN:=StartButton, PT:=T#5s, Q=>MotorOn, ET=>Elapsed);
LightOn turns on 2 seconds after LightSwitch is activated.
PLC Programming
DelayLight(IN:=LightSwitch, PT:=T#2s, Q=>LightOn, ET=>TimePassed);
Sample Program

This program simulates pressing a start button and uses a 3-second on-delay timer. MotorOn becomes true only after 3 seconds.

PLC Programming
PROGRAM OnDelayExample
VAR
  StartButton : BOOL := FALSE;
  MotorOn : BOOL := FALSE;
  Timer1 : TON;
  i : INT;
END_VAR

// Simulate pressing StartButton and running timer
StartButton := TRUE;

// Simulate time passing in 1 second steps
FOR i := 1 TO 4 DO
  Timer1(IN:=StartButton, PT:=T#3s);
  IF Timer1.Q THEN
    MotorOn := TRUE;
  END_IF;
  // Print status
  Print('Second ' + INT_TO_STRING(i) + ': MotorOn=' + BOOL_TO_STRING(MotorOn));
END_FOR
END_PROGRAM
OutputSuccess
Important Notes

If the input turns off before the preset time, the timer resets and output stays off.

The elapsed time (ET) shows how long the timer has been running.

Summary

On-delay timers wait before turning on output after input activates.

They help add delays in automation safely and clearly.

Practice

(1/5)
1. What does an On-delay timer (TON) do in a PLC program?
easy
A. It delays turning off the output after the input is deactivated.
B. It immediately turns on the output when the input is activated.
C. It delays turning on the output after the input is activated.
D. It toggles the output on and off repeatedly.

Solution

  1. Step 1: Understand the function of an On-delay timer

    An On-delay timer waits for a set time after the input signal turns ON before activating the output.
  2. Step 2: Compare options with this behavior

    Only It delays turning on the output after the input is activated. correctly describes this delay before output activation.
  3. Final Answer:

    It delays turning on the output after the input is activated. -> Option C
  4. Quick Check:

    On-delay timer delays output ON = C [OK]
Hint: On-delay means wait before output turns ON [OK]
Common Mistakes:
  • Confusing on-delay with off-delay timer
  • Thinking output turns on immediately
  • Mixing delay before turning off output
2. Which of the following is the correct syntax to declare an On-delay timer named Timer1 with a preset time of 5 seconds in a typical PLC ladder logic?
easy
A. TON Timer1 PT:=T#5s;
B. TON Timer1 PRE 5;
C. TON Timer1, 5s;
D. TIMER TON Timer1 5;

Solution

  1. Step 1: Identify standard TON timer syntax

    In IEC 61131-3 style, TON timers use PT (preset time) with time format like T#5s.
  2. Step 2: Match options to this syntax

    TON Timer1 PT:=T#5s; uses PT:=T#5s which is correct syntax for preset time 5 seconds.
  3. Final Answer:

    TON Timer1 PT:=T#5s; -> Option A
  4. Quick Check:

    Preset time uses PT:=T#5s format [OK]
Hint: Look for PT:=T#5s for preset time in TON [OK]
Common Mistakes:
  • Using incorrect time format like '5s' without T#
  • Missing PT:= keyword for preset time
  • Confusing TON declaration syntax
3. Given the following PLC code snippet using an On-delay timer TON Timer1 with a preset time of 3 seconds:
Timer1(IN:=InputSignal, PT:=T#3s);

// Assume InputSignal turns ON at time 0s
// What is the value of Timer1.Q at 2 seconds?
medium
A. TRUE
B. FALSE
C. Undefined
D. Timer resets

Solution

  1. Step 1: Understand TON behavior with preset 3 seconds

    The output Q turns TRUE only after input is ON continuously for 3 seconds.
  2. Step 2: Check time at 2 seconds

    At 2 seconds, input has been ON less than 3 seconds, so Q remains FALSE.
  3. Final Answer:

    FALSE -> Option B
  4. Quick Check:

    Q turns TRUE after 3s delay, at 2s Q = FALSE [OK]
Hint: Q turns TRUE only after preset time elapsed [OK]
Common Mistakes:
  • Assuming Q is TRUE immediately when input turns ON
  • Confusing preset time with elapsed time
  • Thinking Q toggles before preset time
4. You have this PLC TON timer code snippet:
TON Timer1;
Timer1(IN:=StartButton, PT:=T#4s);

// Output Q is not turning ON even after 5 seconds of StartButton pressed.
// What is the likely error?
medium
A. Preset time PT is set too low.
B. Timer1 is missing a reset instruction.
C. Timer1.Q output is not used correctly.
D. StartButton input is not wired or always FALSE.

Solution

  1. Step 1: Analyze why Q never turns ON after 5 seconds

    If input StartButton never becomes TRUE, timer never starts counting.
  2. Step 2: Check other options

    Preset time 4s is enough; missing reset won't stop Q turning ON; output usage unrelated to timer counting.
  3. Final Answer:

    StartButton input is not wired or always FALSE. -> Option D
  4. Quick Check:

    Input must be TRUE to start timer [OK]
Hint: Check input signal wiring if timer never starts [OK]
Common Mistakes:
  • Assuming timer counts without input TRUE
  • Thinking reset is mandatory to start timer
  • Ignoring input signal state
5. You want to create a safety light that turns ON only if a door remains open for more than 10 seconds continuously. Which PLC On-delay timer setup correctly achieves this behavior?
hard
A. Use a TON timer with input = DoorOpen sensor, PT = 10s, output controls light.
B. Use a TON timer with input = NOT DoorOpen, PT = 10s, output controls light.
C. Use a TOF (off-delay) timer with input = DoorOpen, PT = 10s, output controls light.
D. Use a TON timer with input = DoorOpen sensor, PT = 5s, output controls light.

Solution

  1. Step 1: Identify correct input and delay for safety light

    The light should turn ON only after door is open for 10 seconds, so input must be DoorOpen sensor TRUE and PT = 10s.
  2. Step 2: Evaluate options

    Use a TON timer with input = DoorOpen sensor, PT = 10s, output controls light. matches this exactly. Use a TON timer with input = NOT DoorOpen, PT = 10s, output controls light. uses NOT DoorOpen which is wrong. Use a TOF (off-delay) timer with input = DoorOpen, PT = 10s, output controls light. uses off-delay timer which delays turning OFF, not ON. Use a TON timer with input = DoorOpen sensor, PT = 5s, output controls light. uses 5s delay which is too short.
  3. Final Answer:

    Use a TON timer with input = DoorOpen sensor, PT = 10s, output controls light. -> Option A
  4. Quick Check:

    Delay ON after door open 10s = Use a TON timer with input = DoorOpen sensor, PT = 10s, output controls light. [OK]
Hint: Input = DoorOpen, PT = 10s for delayed ON light [OK]
Common Mistakes:
  • Using off-delay timer instead of on-delay
  • Using inverted input signal
  • Setting delay time too short
Recommended

Ready to prove it?

Pass the test and this pattern moves unknown strong while earning +1 Grip toward your certificate.

10 questions~5 mineasy hard