📖 Scenario: You are working in a factory where two PLCs (Programmable Logic Controllers) need to share data to coordinate their tasks. You will create a simple program to send and receive data between these two PLCs using basic communication tags.
🎯 Goal: Build a PLC program that sets up communication variables, configures a communication status flag, writes data to a send tag, reads data from a receive tag, and finally outputs the received data.
📋 What You'll Learn
Create communication data tags with exact names and values
Add a communication status flag variable
Write data to the send tag using a simple assignment
Read data from the receive tag using a simple assignment
Print or display the received data value
💡 Why This Matters
🌍 Real World
PLC-to-PLC communication is essential in factories where multiple controllers coordinate tasks like assembly lines, packaging, and safety monitoring.
💼 Career
Understanding basic PLC communication helps automation technicians and engineers design reliable control systems that keep industrial processes running smoothly.
Progress0 / 4 steps
1
Create communication data tags
Create two integer variables called send_data and receive_data. Initialize send_data with the value 100 and receive_data with the value 0.
PLC Programming
Hint

Use simple variable assignments to create the tags.

2
Add communication status flag
Create a boolean variable called comm_status and set it to False to represent the communication status.
PLC Programming
Hint

This flag will help track if communication is active.

3
Write and read communication data
Assign the value send_data to a variable called plc_send_tag to simulate sending data. Then assign the value plc_receive_tag to receive_data to simulate receiving data. Assume plc_receive_tag has the value 200.
PLC Programming
Hint

Use simple assignments to simulate data transfer.

4
Output the received data
Print the value of receive_data to display the data received from the other PLC.
PLC Programming
Hint

Use the print function to show the received data.

Practice

(1/5)
1. What is the main purpose of PLC-to-PLC communication?
easy
A. To share data between controllers for coordinated control
B. To program the PLC using a computer
C. To power the PLC devices
D. To store data permanently in the PLC

Solution

  1. Step 1: Understand PLC communication basics

    PLC-to-PLC communication allows multiple controllers to exchange data and work together.
  2. Step 2: Identify the main goal

    The main goal is to share data for coordinated control, not programming or power supply.
  3. Final Answer:

    To share data between controllers for coordinated control -> Option A
  4. Quick Check:

    PLC communication = data sharing [OK]
Hint: PLC communication means controllers talk to share data [OK]
Common Mistakes:
  • Confusing communication with programming
  • Thinking PLC communication powers devices
  • Assuming it stores data permanently
2. Which of the following is the correct syntax to define a Modbus TCP client in a PLC script?
easy
A. modbusClient = ModbusTCPClient('192.168.1.10')
B. modbusClient = TCPModbus('192.168.1.10', 502)
C. modbusClient = ModbusTCP('192.168.1.10', 502)
D. modbusClient = Modbus('192.168.1.10', 80)

Solution

  1. Step 1: Identify correct class and parameters

    The standard syntax uses ModbusTCP with IP and port 502 for Modbus TCP.
  2. Step 2: Check options for correct syntax

    modbusClient = ModbusTCP('192.168.1.10', 502) matches the correct class name and port number for Modbus TCP client.
  3. Final Answer:

    modbusClient = ModbusTCP('192.168.1.10', 502) -> Option C
  4. Quick Check:

    ModbusTCP + port 502 = correct client syntax [OK]
Hint: Modbus TCP uses port 502 and class ModbusTCP [OK]
Common Mistakes:
  • Using wrong class names like TCPModbus
  • Using incorrect port numbers
  • Omitting the port parameter
3. Given the following PLC script snippet for sending a signal:
modbusClient.write_coil(1, True)
status = modbusClient.read_coil(1)

What will be the value of status after execution?
medium
A. False
B. Error
C. 0
D. True

Solution

  1. Step 1: Understand write_coil and read_coil functions

    write_coil(1, True) sets coil 1 to True; read_coil(1) reads its current value.
  2. Step 2: Trace the code execution

    After writing True to coil 1, reading coil 1 returns True.
  3. Final Answer:

    True -> Option D
  4. Quick Check:

    Write True then read coil = True [OK]
Hint: Write True, then read coil returns True [OK]
Common Mistakes:
  • Assuming read_coil returns False immediately
  • Confusing coil values with integers
  • Expecting an error without connection
4. Identify the error in this PLC-to-PLC communication code snippet:
modbusClient = ModbusTCP('192.168.1.20')
modbusClient.write_register(10, 123)
medium
A. Missing port number in ModbusTCP initialization
B. write_register function does not exist
C. IP address format is incorrect
D. Register address 10 is invalid

Solution

  1. Step 1: Check ModbusTCP initialization parameters

    ModbusTCP requires IP address and port number (usually 502).
  2. Step 2: Identify missing port parameter

    The code only provides IP, missing port number causes connection error.
  3. Final Answer:

    Missing port number in ModbusTCP initialization -> Option A
  4. Quick Check:

    ModbusTCP needs IP and port [OK]
Hint: Always include port number when creating ModbusTCP client [OK]
Common Mistakes:
  • Forgetting the port number argument
  • Assuming default port without specifying
  • Misreading IP address format
5. You want to synchronize two PLCs so that PLC A sends a temperature value to PLC B every second using Modbus TCP. Which approach best ensures reliable data transfer?
hard
A. PLC A sends temperature as a coil value; PLC B reads it once at startup
B. PLC A writes the temperature to a holding register; PLC B reads it every second with error checking
C. PLC B writes a command to PLC A; PLC A sends temperature only on command
D. PLC A broadcasts temperature on UDP; PLC B listens without confirmation

Solution

  1. Step 1: Identify reliable data transfer method

    Using holding registers with regular writes and reads plus error checking is reliable.
  2. Step 2: Evaluate other options

    Coils are for binary signals, not values; reading once or UDP without confirmation is unreliable.
  3. Final Answer:

    PLC A writes the temperature to a holding register; PLC B reads it every second with error checking -> Option B
  4. Quick Check:

    Regular register write/read with error check = reliable [OK]
Hint: Use holding registers and error checks for reliable data [OK]
Common Mistakes:
  • Using coils for analog values
  • Reading data only once instead of periodically
  • Using UDP without confirmation for critical data