PLC Programmingscripting~5 mins

Modbus RTU communication in PLC Programming - Cheat Sheet & Quick Revision

Choose your learning style10 modes available
Recall & Review
beginner
What is Modbus RTU communication?
Modbus RTU is a serial communication protocol used to connect industrial electronic devices. It sends data in a compact binary format over serial lines like RS-485.
Click to reveal answer
beginner
What are the main components of a Modbus RTU message frame?
A Modbus RTU frame includes: a device address, function code, data, and a CRC checksum to check errors.
Click to reveal answer
beginner
Why is CRC used in Modbus RTU communication?
CRC (Cyclic Redundancy Check) helps detect errors in the message during transmission to ensure data integrity.
Click to reveal answer
beginner
How does a Modbus RTU master device communicate with slaves?
The master sends a request to a slave using its address. The slave responds with the requested data or an error message.
Click to reveal answer
beginner
What serial settings are important for Modbus RTU communication?
Key settings include baud rate (speed), parity (error checking), data bits, and stop bits. Both devices must match these settings.
Click to reveal answer
What does RTU stand for in Modbus RTU?
ARemote Transfer Utility
BReal-Time Unit
CRemote Terminal Unit
DReliable Transmission Unit
Which layer does Modbus RTU operate on?
AApplication layer
BPhysical layer
CNetwork layer
DData link layer
What is the purpose of the device address in Modbus RTU?
ATo identify the slave device
BTo set baud rate
CTo check message errors
DTo identify the master device
Which serial communication parameter must match on both Modbus RTU devices?
AIP address
BBaud rate
CMAC address
DPort number
What happens if CRC check fails in a Modbus RTU message?
AMessage is accepted
BMessage is encrypted
CMessage is resent automatically
DMessage is ignored or error reported
Explain how a Modbus RTU master communicates with slave devices.
Think about the request-response pattern and addressing.
You got /5 concepts.
    Describe the importance of serial communication settings in Modbus RTU.
    Consider what happens if settings differ between devices.
    You got /5 concepts.

      Practice

      (1/5)
      1. What is the main purpose of Modbus RTU communication in PLC programming?
      easy
      A. To exchange data between devices over serial communication
      B. To create graphical user interfaces
      C. To compile PLC programs
      D. To store data in cloud servers

      Solution

      1. Step 1: Understand Modbus RTU basics

        Modbus RTU is a protocol used for serial communication between devices like PLCs and sensors.
      2. Step 2: Identify the main function

        Its main function is to exchange data by sending requests and responses over serial lines.
      3. Final Answer:

        To exchange data between devices over serial communication -> Option A
      4. Quick Check:

        Modbus RTU = Data exchange over serial [OK]
      Hint: Modbus RTU is about device data exchange via serial lines [OK]
      Common Mistakes:
      • Confusing Modbus RTU with programming languages
      • Thinking it creates user interfaces
      • Assuming it stores data remotely
      2. Which of the following is the correct format for a Modbus RTU request frame?
      easy
      A. CRC + Device Address + Function Code + Data
      B. Device Address + Function Code + Data + CRC
      C. Data + Device Address + Function Code + CRC
      D. Function Code + Device Address + Data + CRC

      Solution

      1. Step 1: Recall Modbus RTU frame structure

        The request frame starts with the device address, followed by the function code, then data, and ends with CRC for error checking.
      2. Step 2: Match the correct sequence

        Device Address + Function Code + Data + CRC matches this exact order: Device Address + Function Code + Data + CRC.
      3. Final Answer:

        Device Address + Function Code + Data + CRC -> Option B
      4. Quick Check:

        Frame order = Address, Function, Data, CRC [OK]
      Hint: Remember: Address first, then function, data, and CRC last [OK]
      Common Mistakes:
      • Mixing up the order of function code and device address
      • Placing CRC at the start instead of the end
      • Confusing data position in the frame
      3. Given this Modbus RTU request frame in hex: 01 03 00 0A 00 02 C5 CD, what does the function code 03 represent?
      medium
      A. Write Multiple Registers
      B. Write Single Coil
      C. Read Input Status
      D. Read Holding Registers

      Solution

      1. Step 1: Identify the function code in the frame

        The second byte in the frame is 03, which is the function code.
      2. Step 2: Recall Modbus function codes

        Function code 03 is used to read holding registers in Modbus RTU communication.
      3. Final Answer:

        Read Holding Registers -> Option D
      4. Quick Check:

        Function code 03 = Read Holding Registers [OK]
      Hint: Function code 03 always reads holding registers [OK]
      Common Mistakes:
      • Confusing function code 03 with write operations
      • Mixing read input status (code 02) with 03
      • Ignoring the function code position in the frame
      4. You wrote a Modbus RTU request but the PLC does not respond. Which of these is the most likely error in your request frame?
      medium
      A. Using ASCII instead of RTU mode
      B. Sending data without device address
      C. Incorrect CRC value
      D. Using function code 99

      Solution

      1. Step 1: Check common communication errors

        Incorrect CRC causes the PLC to reject the frame because it detects data corruption.
      2. Step 2: Evaluate other options

        Using ASCII mode or missing device address would cause errors, but CRC error is the most common cause of no response. Function code 99 is invalid but usually triggers an error response, not silence.
      3. Final Answer:

        Incorrect CRC value -> Option C
      4. Quick Check:

        Bad CRC = No response from PLC [OK]
      Hint: Always verify CRC to avoid silent communication failures [OK]
      Common Mistakes:
      • Ignoring CRC errors
      • Assuming wrong function code causes no response
      • Confusing ASCII and RTU modes
      5. You want to read 4 consecutive holding registers starting at address 100 from a device with address 5 using Modbus RTU. Which request frame (in hex) correctly represents this?
      hard
      A. 05 03 00 64 00 04 45 C9
      B. 05 04 00 64 00 04 45 C9
      C. 01 03 00 64 00 04 45 C9
      D. 05 03 00 65 00 04 45 C9

      Solution

      1. Step 1: Understand the frame components

        Device address is 05, function code for reading holding registers is 03, starting address 100 in hex is 00 64, number of registers to read is 00 04, followed by CRC.
      2. Step 2: Check each option

        05 03 00 64 00 04 45 C9 matches all these correctly. 05 04 00 64 00 04 45 C9 uses function code 04 (read input registers), 01 03 00 64 00 04 45 C9 uses device address 01, and 05 03 00 65 00 04 45 C9 starts at address 101 (00 65).
      3. Final Answer:

        05 03 00 64 00 04 45 C9 -> Option A
      4. Quick Check:

        Address 5 + Func 03 + Start 100 + Count 4 = 05 03 00 64 00 04 45 C9 [OK]
      Hint: Match device address, function code, start address, and count exactly [OK]
      Common Mistakes:
      • Using wrong function code for holding registers
      • Incorrect device address
      • Off-by-one error in start address