PLC Programmingscripting~10 mins

Level control system in PLC Programming - Interactive Code Practice

Choose your learning style10 modes available
Practice - 5 Tasks
Answer the questions below
1fill in blank
easy

Complete the code to start the pump when the level is low.

PLC Programming
IF level_sensor = [1] THEN
    pump := TRUE;
END_IF;
Drag options to blanks, or click blank then click option'
ALOW
BOFF
CON
DHIGH
Attempts:
3 left
💡 Hint
Common Mistakes
Using HIGH instead of LOW to start the pump.
Confusing pump ON/OFF with sensor states.
2fill in blank
medium

Complete the code to stop the pump when the level is high.

PLC Programming
IF level_sensor = [1] THEN
    pump := FALSE;
END_IF;
Drag options to blanks, or click blank then click option'
ALOW
BHIGH
CON
DOFF
Attempts:
3 left
💡 Hint
Common Mistakes
Stopping the pump when the level is LOW instead of HIGH.
Mixing sensor states with pump states.
3fill in blank
hard

Fix the error in the code to correctly check the level sensor and control the pump.

PLC Programming
IF level_sensor [1] HIGH THEN
    pump := FALSE;
ELSE
    pump := TRUE;
END_IF;
Drag options to blanks, or click blank then click option'
A!=
B=
C<>
D==
Attempts:
3 left
💡 Hint
Common Mistakes
Using '=' instead of '==' for comparison.
Using '!=' or '<>' which may not be supported in this context.
4fill in blank
hard

Fill both blanks to create a condition that starts the pump only when the level is low and the emergency stop is not active.

PLC Programming
IF level_sensor = [1] AND emergency_stop = [2] THEN
    pump := TRUE;
END_IF;
Drag options to blanks, or click blank then click option'
ALOW
BTRUE
CFALSE
DHIGH
Attempts:
3 left
💡 Hint
Common Mistakes
Using HIGH instead of LOW for level_sensor.
Using TRUE for emergency_stop which means the stop is active.
5fill in blank
hard

Fill all three blanks to create a dictionary mapping sensor names to their states, filtering only sensors that are active (TRUE).

PLC Programming
active_sensors = { [1]: [2] for [1] in sensors if sensors[[1]] == TRUE }
Drag options to blanks, or click blank then click option'
Asensor
Bsensors[sensor]
Dstate
Attempts:
3 left
💡 Hint
Common Mistakes
Using different variable names inconsistently.
Not filtering sensors that are TRUE.

Practice

(1/5)
1. What is the main purpose of a level control system in a tank?
easy
A. To measure the temperature of the liquid
B. To keep the liquid level within safe limits automatically
C. To change the color of the liquid
D. To increase the pressure inside the tank

Solution

  1. Step 1: Understand the system goal

    A level control system is designed to maintain liquid levels safely.
  2. Step 2: Identify the correct function

    It uses sensors and pumps to keep levels steady, not temperature or color.
  3. Final Answer:

    To keep the liquid level within safe limits automatically -> Option B
  4. Quick Check:

    Level control = safe liquid level [OK]
Hint: Focus on what 'level control' means in real life [OK]
Common Mistakes:
  • Confusing level control with temperature control
  • Thinking it changes liquid properties
  • Assuming it controls pressure
2. Which of the following is the correct simple IF statement to turn ON a pump when the level is below 30%?
easy
A. IF level = 30 THEN pump = OFF;
B. IF level > 30 THEN pump = ON;
C. IF level < 30 THEN pump = ON;
D. IF level <= 30 THEN pump = OFF;

Solution

  1. Step 1: Understand the condition for turning pump ON

    The pump should turn ON when level is below 30% to fill the tank.
  2. Step 2: Match the correct syntax

    IF level < 30 THEN pump = ON; correctly uses IF level < 30 THEN pump = ON;
  3. Final Answer:

    IF level < 30 THEN pump = ON; -> Option C
  4. Quick Check:

    Turn ON pump if level less than 30% [OK]
Hint: Pump ON when level is less, so use '<' operator [OK]
Common Mistakes:
  • Using > instead of < for turning pump ON
  • Confusing ON and OFF states
  • Using equality instead of inequality
3. Given this PLC logic snippet:
IF level < 40 THEN pump = ON;
ELSE pump = OFF;

What will be the pump state if the level sensor reads 45?
medium
A. Pump will be ON
B. Pump will stay in previous state
C. Pump state will toggle rapidly
D. Pump will be OFF

Solution

  1. Step 1: Check the condition with level = 45

    Since 45 is not less than 40, the IF condition is false.
  2. Step 2: Follow the ELSE branch

    Because IF is false, pump = OFF is executed.
  3. Final Answer:

    Pump will be OFF -> Option D
  4. Quick Check:

    Level 45 ≥ 40 means pump OFF [OK]
Hint: Check IF condition with given value carefully [OK]
Common Mistakes:
  • Assuming pump stays ON without checking ELSE
  • Confusing < and > operators
  • Ignoring ELSE branch
4. Identify the error in this PLC code snippet for level control:
IF level > 70 THEN pump = ON;
ELSE pump = ON;
medium
A. Pump is always ON regardless of level
B. Syntax error: missing ENDIF
C. Pump never turns ON
D. Level sensor value is not checked

Solution

  1. Step 1: Analyze the IF and ELSE assignments

    Both IF and ELSE branches set pump = ON, so pump is always ON.
  2. Step 2: Understand the logic flaw

    This means pump never turns OFF, ignoring level changes.
  3. Final Answer:

    Pump is always ON regardless of level -> Option A
  4. Quick Check:

    Same action in IF and ELSE means no control [OK]
Hint: Check if IF and ELSE do different things [OK]
Common Mistakes:
  • Thinking ELSE is missing
  • Assuming pump turns OFF somewhere
  • Ignoring logic duplication
5. You want to design a level control system that turns ON the pump when level is below 30%, turns OFF when above 70%, and keeps the pump state unchanged between 30% and 70%. Which logic correctly implements this?
hard
A. IF level < 30 THEN pump = ON; ELSE IF level > 70 THEN pump = OFF;
B. IF level <= 70 THEN pump = OFF; ELSE pump = ON;
C. IF level < 30 THEN pump = ON; ELSE pump = OFF;
D. IF level > 70 THEN pump = ON; ELSE IF level < 30 THEN pump = OFF;

Solution

  1. Step 1: Understand the required behavior

    Turn pump ON below 30%, OFF above 70%, and keep state unchanged between 30% and 70%.
  2. Step 2: Analyze each option

    IF level < 30 THEN pump = ON; ELSE IF level > 70 THEN pump = OFF; turns ON if level < 30, OFF if level > 70, and does nothing in between (keeps state).
  3. Final Answer:

    IF level < 30 THEN pump = ON; ELSE IF level > 70 THEN pump = OFF; -> Option A
  4. Quick Check:

    Two conditions control pump ON/OFF, else no change [OK]
Hint: Use two IFs for ON and OFF, no ELSE for unchanged [OK]
Common Mistakes:
  • Turning pump OFF immediately below 70%
  • Not handling the middle range correctly
  • Reversing ON and OFF conditions